The Cluster Wave Experiment Consortium


WEC commissioning

This page summarizes the status of the commissioning of the Cluster WEC instruments.

Latest status

The final deploymentof the last pair of booms on SC4 took place on 16 November. This completed the sequence of boom deployments, which have all been successful, and was followed by a small celebration at ESOC. See also the story at the Cluster home page.

At the end of last week, 9-10 November, a major event on the Sun compressed the magnetosphere so that the spacecraft entered the magnetosheath several times. It also caused disturbances to the operation of some instruments, including WEC.

Event timeline

The table below gives details of when the various steps in the WEC commissioning were performed on the different spacecraft. For more information on each step, please consult the WEC User Manual.
 
Date/Time
UT
Spacecraft 1
Rumba
Spacecraft 2
Salsa
Spacecraft 3
Samba
Spacecraft 4
Tango
         
000825 0003-0026   A2 1st WEC on    
000825 0056-0115   A2 redundant i/f    
000825 0136-0215    A4 1st full WEC on    
000825 0218-0404    A3 DWP checkout    
000825 0407   A5 DWP+EFW on    
000825 0415-0425   A6 EFW verif (incomplete)    
000825 0445-0455   A6 EFW verif    
000825 0555-0605   A8 EFW verif    
         
000829 1842-1915 A2 1st WEC on      
000829 2003-2022 A2 redundatnt i/f      
000829 2051-2129 A4 1st full WEC on      
000829 2137-2323 A3 DWP checkout      
000829 2326 A5 DWP+EFW on      
000829 2340-2350 A6 EFW verif      
000830 0020-0030 A8 EFW verif      
000830 0110-0140 B6 EFW diagnostics      
         
000905 1647   B1 DWP+EFW on    
000905 1726   B2 Open covers on units 1+2    
000905 1743   B2 Open covers on units 3+4    
000905 1812-1816   B3 Booms 3+4: 0-3 m
Spin: 15.04-14.95 rpm
   
000905 1826-1843   B3 Booms 3+4: 3-15 m
Spin: 14.95-13.35 rpm
   
000905 1904-1910   B4 Booms 1+2: 0-3 m
Spin: 13.35-13.27 rpm
   
000905 1920-1940   B4 Booms 1+2: 3-15 m
Spin: 13.27-11.97 rpm
   
000905 2100-2102   B5 Spin up: 11.97-21.86 rpm    
000905 2145-2220   B6 EFW diagnostics    
000905 2225   B7a WHISPER diagnostics    
000905 2245   B7b WHISPER diagnostics    
000905 2320   B8 STAFF diagnostics    
000905 2355   B9 WBD BM2 diagnostics    
000906 0115-0145   B10 WBD DSN diagnostics    
         
000907 2028 B1 DWP+EFW on      
000907 2054 B2 Open covers on units 1+2      
000907 2104 B2 Open covers on units 3+4      
000907 2123-2128 B3 Booms 3+4: 0-3 m
Spin: 15.14-15.04 rpm
     
000907 2141-2201 B3 Booms 3+4: 3-15 m
Spin: 15.04-13.43 rpm
     
000907 2221-2227 B4 Booms 1+2: 0-3 m
Spin: 13.43-13.34 rpm
     
000907 2255-2320 B4 Boom 1: 3-15 m
Boom 2: 2-18.5 m
Spin: 13.34-11.71 m
     
000908 0100-0102 B5 Spin up: 11.71-21.77 rpm      
000908 0120-0200 B6 EFW diagnostics      
000908 0215 B7a WHISPER diagnostics      
000908 0235 B7b WHISPER diagnostics      
000908 0305 B8 STAFF diagnostics      
000908 0350 B9 WBD BM2 diagnostics      
000908 1014-1044 B10 WBD DSN diagnostics
(not captured by DSN)
     
         
000909 0226-0536   B10.1 WEC diagnostics    
000909 2115-0031   B10.4 WEC diagnostics    
         
000912 1037   C1 DWP+EFW on    
000912 1114-1142   C2 Booms 3+4: 15-35 m
Spin: 21.84-14.33 rpm
   
000912 1211-1219   C3 Booms 1+2: 15-20 m
Spin: 14.33-13.58 rpm
   
000912 1235-1310   C4 EFW diagnostics    
000912 1315   C5 WHISPER diagnostics    
000912 1350   C6 STAFF diagnostics    
         
000913 1208-1518   C7.1 WEC diagnostics    
000914 1402-1417   C8 WBD BM2 diagnostics    
000914 1442-1801   C7.4 WEC diagnostics    
         
000916 0250-0600 B10.1 WEC diagnostics      
000916 2209-0124 B10.4 WEC diagnostics      
         
000918 2000   D0 Spin up: 13.58-17.48 rpm    
000918 2037   D1 DWP+EFW on    
000918 2113-2122   D2 Booms 3+4: 35-41 m
Spin: 17.48-14.96 rpm
   
000918 2127-2135   D4 EFW diagnostics (aborted)    
000918 2138-2213   D4 EFW diagnostics    
000918 2235   D5 WHISPER diagnostics    
000918 2308   D6 STAFF diagnostics    
000918 2345   E9 STAFF HBR diagnostics    
         
000920 1425-1735   D7.1 WEC diagnostics    
         
000920 1833 C1 DWP+EFW on      
000920 1907-1939 C2 Booms 3+4: 15-35 m
Spin: 21.79-14.45 rpm
     
000920 2006-2013 C3 Boom 1: 15-20 m
Spin: 14.45-14.07 rpm
     
000920 2028-2030 C3 Boom 2: 18.5-20 m
Spin: 14.07-13.94 rpm
     
000920 2045-2120 C4 EFW diagnostics      
000920 2128-2154 C5 WHISPER diagnostics      
000920 2156-2228 C6 STAFF diagnostics      
         
000921 0214-0244 WBD DSN diagnostics      
000921 1720-1735   D8 WBD BM2 diagnostics    
000921 1720-2030 C7.1 WEC diagnostics      
000921 1740-2056   D7.4 WEC diagnostics    
000923 0409-0726 C7.4 WEC diagnostics D9.1 WEC diagnostics    
000923 0739-0754 C8 WBD BM2 diagnostics D10 WBD BM2 diagnostics    
000924 0535-0848   D9.4 WEC diagnostics    
         
000925 1938-1940 D0 Spin up: 13.94-17.54 rpm      
000925 1953 D1 DWP+EFW on      
000925 2016-2026 D2 Booms 3+4: 35-41 m
Spin: 17.54-15.03 rpm
     
000925 2035-2110 D4 EFW diagnostics      
000925 2117-2143 D5 WHISPER diagnostics      
000925 2150-2222 D6 STAFF diagnostics      
000925 2225 E9 STAFF HBR diagnostics      
         
000926 1536-1846 D7.1 WEC diagnostics      
000927 2314- D7.4 WEC diagnostics      
000927 2320-0230   D11.1 WEC diagnostics    
000928 0245 D8 WBD BM2 diagnostics      
000928 1944-1959   D12 WBD BM2 diagnostics    
000928 2004-2317   D11.4 WEC diagnostics    
000930 0501-0811 D9.1 WEC diagnostics      
000930 0835-0850 D10 WBD BM2 diagnostics      
001001 0951-1304 D9.4 WEC diagnostics      
         
001004 1651   E1 DWP+EFW on    
001004 1728-1802   E2 Booms 1+2: 20-41 m
Spin: 14.95-10.81 rpm
   
001004 1931-1933   E3 Spin up: 10.81-14.97 rpm    
001004 1945-2020   E4 EFW diagnostics    
001004 2045-2111   E5 WHISPER diagnostics    
001004 2113-2145   E6 STAFF diagnostics    
         
001005 0113-0423 D11.1 WEC diagnostics E7.1 WEC diagnostics    
001006 0132-0444 D11.4 WEC diagnostics E7.4 WEC diagnostics    
001006 0502-0522 D12 WBD BM2 diagnostics E8 WBD BM2 diagnostics    
001006 1030-1100   E9.1 EFW HBR diagnostics
(bad due to wrong SC TM mode)
   
001006 1100-1135   E9.2 STAFF HBR diagnostics
(bad due to wrong SC TM mode)
   
001006 1135-1200   E10 WBD BM2 diagnostics
(bad due to wrong WEC clock setting)
   
         
001006 1446 E1 DWP+EFW on      
001006 1509-1746 E2 Booms 1+2: 20-41 m
Spin: 15.02-10.84 rpm
(deployment done in 13 steps)
     
001006 1945-1947 E3 Spin up: 10.84-15.01 rpm      
001006 2010-2045 E4 EFW diagnostics      
001006 2100-2126 E5 WHISPER diagnostics
(bad due to saturated EFW probes)
     
001006 2146-2218 E6 STAFF diagnostics      
001006 2224-2250 E5 WHISPER diagnostics
(rerun, bad due to buffer overflow)
     
         
001007 0549 E7.1 WEC diagnostics      
001007 2101-2136   E9.b WHISPER HBR diagn
(bad due to WHISPER off)
   
001007 2136-2206   E9.c WHISPER HBR diagn
(bad due to WHISPER off)
   
001008 0839 E7.4 WEC diagnostics      
001008 1209 E8 WBD BM2 diagnostics      
001008 2317 E9.1 EFW HBR diagnostics      
001008 2347 E9.2 STAFF HBR diagnostics      
001009 0008 E10 WBD BM2 diagnostics      
         
001009 0833-0857     A2 1st WEC on  
001009 0931-0953     A2 redundant i/f  
001009 1015-1053     A4 1st full WEC on  
001009 1056-1243     A3 DWP checkout  
001009 1249     A5 DWP+EFW on  
001009 1300-1325     A6 EFW verif  
001009 1405-1415     A8 EFW verif  
         
001009 1256-1331 E9.b WHISPER HBR diagn
(bad due to WHISPER off)
     
001009 1331-1401 E9.c WHISPER HBR diagn
(bad due to WHISPER off)
     
001009 1906 F1 Full EFW tests F1 Full EFW tests    
001009 2107 F2 Full WHISPER tests F2 Full WHISPER tests
(bad due to WHISPER off)
   
001010 0008 F3 Full STAFF tests F3 Full STAFF tests    
001010 0108 F4 Full WBD BM2 test F4 Full WBD BM2 test    
001010 0138 F4 Full WBD BM2 test F4 Full WBD BM2 test    
001010 0238 F5 Full WEC macro tests
(bad due to WHISPER off) 
F5 Full WEC macro tests
(bad due to WHISPER off)
   
001011 0500 F6a Full WEC macro tests (HBR) F6a Full WEC macro tests (HBR)
(bad due to WHISPER off)
   
001011 0600 F6b Full WEC macro tests (HBR) F6b Full WEC macro tests (HBR)
(bad due to WHISPER off)
   
001011 0730 F7 WEC interference tests (HBR) F7 WEC interference tests (HBR)    
001011 1100   F8 WEC interference tests (LBR)    
001011 1230   WBD DSN diagnostics    
         
001011 1629     B1 DWP+EFW on  
001011 1654     B2 Open covers on units 1+2  
001011 1706     B2 Open covers on units 3+4  
001011 1736-1741     B3 Booms 3+4: 0-3 m
Spin: 14.96-14.86 rpm
 
001011 1759-1820     B3 Booms 3+4: 3-15 m
Spin: 14.86-13.24 rpm
 
001011 1838-1843     B4 Booms 1+2: 0-3 m
Spin: 13.24-13.17 rpm
 
001011 1849-1909     B4 Booms 1+2: 3-15 m
Spin: 13.17-11.88 rpm
 
001011 2059-2101     B5 Spin up: 11.88-21.83 rpm  
001011 2125-2200     B6 EFW diagnostics  
001011 2215     B7a WHISPER diagnostics  
001011 2239-2305     B7b WHISPER diagnostics  
001011 2311-2343     B8 STAFF diagnostics  
001012 0005-0025     B9 WBD BM2 diagnostics  
         
001012 0227-0537     B10.1 WEC diagnostics  
001012 0627-0700     B10 WBD DSN diagnostics  
001013 0356-0712     B10.4 WEC diagnostics  
001013 0726-0746     B11 WBD BM2 diagnostics  
001016 0200 F8 WEC interference tests (LBR)      
001016 0330 WBD DSN diagnostics      
         
001016 1622     C1 DWP+EFW on  
001016 1657-1730     C2 Booms 3+4: 15-35 m
Spin: 21.82-14.26 rpm
 
001016 1752-1800     C3 Booms 1+2: 15-20 m
Spin: 14.26-13.53 rpm
 
001016 1818-1853     C4 EFW diagnostics  
001016 1925     C5 WHISPER diagnostics  
001016 1958-2030     C6 STAFF diagnostics  
         
001017 0004-0314     C7.1 WEC diagnostics  
001017 2207-0127     C7.4 WEC diagnostics  
001018 0138-0158     C8 WBD BM2 diagnostics  
001018 0730   E9.1 EFW HBR diagnostics (rerun)    
001018 0755   E9.2 STAFF HBR diagnostics (rerun)    
001018 0820 E9.b WHISPER HBR diagn (rerun) E9.b WHISPER HBR diagn (rerun)    
001018 0855 E9.c WHISPER HBR diagn (rerun) E9.c WHISPER HBR diagn (rerun)    
         
001018 1454     D1 DWP+EFW on  
001018 1529-1521     D0 Spin up: 13.53-17.50 rpm  
001018 1617-1627     D2 Booms 3+4: 35-41 m
Spin: 17.50-14.97 rpm
 
001018 1650-1725     D4 EFW diagnostics  
001018 1740     D5 WHISPER diagnostics  
001018 1815     D6 STAFF diagnostics  
         
001019 0333-0643     D7.1 WEC diagnostics  
001019 2200   F2 Full WHISPER tests (rerun)
(bad due to DWP SEU?)
   
001020 0100 F5 Full WEC macro tests (rerun) F5 Full WEC macro tests (rerun)
(bad due to DWP SEU?)
   
001020 0200   F6a Full WEC macro tests (HBR) (rerun)
(bad due to DWP SEU?)
   
001020 0300   F6a Full WEC macro tests (HBR) (rerun)
(bad due to DWP SEU?)
   
001020 0713-1033     D7.4 WEC diagnostics  
001020 1043     D8 WBD BM2 diagnostics  
001020 1607 OBDH reboot, all instr off      
001022 1620     D9.1 WEC diagnostics  
         
001023 1444   EFW reset due to bad sweeps    
001023 1548-1600  WEC restarted in passive mode      
         
001023 1702-1725       A2 1st WEC on
001023 1753-1814       A2 redundant i/f
001023 1846-1929       A4 1st full WEC on
001023 1932-2119       A3 DWP checkout
001023 2034-2052   WEC restarted in passive mode    
001023 2131       A5 DWP+EFW on
001023 2145-2155       A6 EFW verif
001023 2219-2229       A8 EFW verif
         
001024 0038     D9.4 WEC diagnostics  
001024 0408     D10 WBD BM2 diagnostics  
001025 1646-1648       B1 DWP+EFW on
001025 1716       B2 Open covers on units 1+2
001025 1726       B2 Open covers on units 3+4
001025 1756-1801       B3 Booms 3+4: 0-3 m
Spin: 15.10-15.00 rpm
001025 1811-1833       B3 Booms 3+4: 3-15 m
Spin: 15.00-13.36 rpm
001025 1904-1909       B4 Booms 1+2: 0-3 m
Spin: 13.36-13.28 rpm
001025 1927-1947       B4 Booms 1+2: 3-15 m
Spin: 13.28-11.99 rpm
001025 2025-2100       B6 EFW diagnostics
001025 2113       B7a WHISPER diagnostics
001025 2133       B7b WHISPER diagnostics
001025 2210       B8 STAFF diagnostics
001025 2255-2316       B9 WBD BM2 diagnostics
(bad due to TM buffer overflow)
001025 2320-2341       B9 WBD BM2 diagnostics (rerun)
001026 0100-0133       B10 WBD DSN diagnostics
(bad due to non-scheduling)
         
001026 1345-1347       B5 Spin up: 11.99-21.86 rpm
001026 1416-1451       B6 EFW diagnostics
         
001026 2131-0041     D11.1 WEC diagnostics  
001027 1034-1344       B10.1 WEC diagnostics
001027 1034-1354     D11.4 WEC diagnostics  
001027 1404     D12 WBD BM2 diagnostics B10 WBD BM2 diagnostics
001028 0959-1319       B10.4 WEC diagnostics
         
001030 1434-1436       C1 DWP+EFW on
001030 1506-1540       C2 Booms 3+4: 15-35 m
Spin: 21.86-14.23 rpm
001030 1608-1616       C3 Booms 1+2: 15-20 m
Spin: 14.23-13.50 rpm
001030 1635-1710       C4 EFW diagnostics
001030 1746       C5 WHISPER diagnostics
001030 1820-1852       C6 STAFF diagnostics
         
001031 0442-0752       C7.1 WEC diagnostics
001031 1452-1535   WEC off during CIS test    
001101 0444-0804       C7.4 WEC diagnostics
001101 0814-0834       C8 WBD BM2 diagnostics
001101 1705-1717 WEC reset      
         
001102 1615-1616       D0 Spin up: 13.50-17.51 rpm
001102 1627-1629       D1 DWP+EFW on
001102 1650-1700       D2 Booms 3+4: 35-41 m
Spin: 17.51-14.95 rpm
001102 1725-1800       D4 EFW diagnostics
(partly bad due to VILSPA power outage)
001102 1810-1825       D4 EFW diagnostics
(rerun first 15 minutes)
001102 1835-1901       D5 WHISPER diagnostics
001102 1905-1937       D6 STAFF diagnostics
001102 1940-2000       E9 STAFF HBR diagnostics
         
001104 0800-0830       B10 WBD DSN diagnostics (rerun)
001104 2253-0203       D7.1 WEC diagnostics
001105 2357-0317       D7.4 WEC diagnostics
001106 0328-0348       D8 WBD BM2 diagnostics
         
001108 1409-1411     E1 DWP+EFW on  
001108 1435-1508     E2 Booms 1+2: 20-41 m
Spin: 14.96-10.84 rpm
 
001108 1533-1508     E4 EFW diagnostics  
001108 1618     E5 WHISPER diagnostics  
001108 1646     E6 STAFF diagnostics  
001108 1725-1800     E4 EFW diagnostics  
         
001108 2120-0030     E7.1 WEC diagnostics  
001109 0553     WEC switched off by OBDH  
         
001109 1151-1511     E7.4 WEC diagnostics
(not run due to OBDH switch-off)
 
001109 1313-1337   WEC off-on due to DWP problems    
001109 1521-1541     E8 WBD BM2 diagnostics
(not run due to OBDH switch-off)
 
001109 1552   DWP problems start    
001109 1709-2019       D9.1 WEC diagnostics
001109 ca 2000     E3 Spin up: 10.84-ca 15 rpm
(not run due to OBDH problems)
 
001110 0000     E9.1 EFW HBR diagnostics
(not run due to OBDH switch-off)
 
001110 0030     E9.2 STAFF HBR diagnostics
(not run due to OBDH switch-off)
 
001110 0100     E10 WBD HBR diagnostics
(not run due to OBDH switch-off)
 
001110 0120     E9.b WHISPER HBR diagnostics
(not run due to OBDH switch-off)
 
001110 0155     E9.c WHISPER HBR diagnostics
(not run due to OBDH switch-off)
 
001110 1306     WEC switched on  
001110 1712-2032       D9.4 WEC diagnostics
001110 2042-2102       D10 WBD BM2 diagnostics
001111 0400     E9.1 EFW HBR diagnostics  
001111 0430     E9.2 STAFF HBR diagnostics  
001111 0500     E10 WBD HBR diagnostics  
001111 0520     E9.b WHISPER HBR diagnostics  
001111 0555     E9.c WHISPER HBR diagnostics  
001111 1204   DWP reset    
001111 1350-1359 WEC off-on due to DWP problem?      
001111 2000-2002     E3 Spin up: 10.84-14.99 rpm  
001113 1200-1510       D11.1 WEC diagnostics
001114 0318-0338       D12 WBD BM2 diagnostics
001114 0340-0700       D11.4 WEC diagnostics
001114 2300-2335 B6X EFW diagnostics B6X EFW diagnostics    
001115 1900-2130   WBD multi sc ops
(failed due to ??)
WBD multi sc ops
(failed tue to ??)
 
001116 0220     F1 Full EFW tests
(bad due to wrong CAB?)
 
001116 0420     F2 Full WHISPER tests
(bad due to wrong CAB?)
 
001116 0720     F3 Full STAFF tests
(bad due to wrong CAB?)
 
001116 0820     F4 Full WBD BM2 tests  
001116 0920     F5 Full WEC macro tests  
001116 1420-1422       E1 DWP+EFW on
001116 1450-1525       E2 Booms 1+2: 20-41 m
Spin: 14.94-10.83 rpm
001116 1612-1647       E4 EFW diagnostics
001116 1703-1729       E5 WHISPER diagnostics
001116 1800-1802       E3 Spin up: 10.83-14.98 rpm
001116 1815       E6 STAFF diagnostics
001116 2000     F6a Full WEC macro tests (HBR)  
001116 2023-2333       E7.1 WEC diagnostics
001116 2100     F6b Full WEC macro tests (HBR)  
001116 2230     F7 WEC interference tests (HBR)  
001117 0725   WEC switched off by OBDH    
001117 2027-2347       E7.4 WEC diagnostics
(bad from 2130 due to ?)
001117 2357-0017       E8 WBD BM2 diagnostics
(bad from 00:13 due to ?)
001118 2218-2324   WEC switched on    
001119 0507     F8 WEC interference tests (LBR)  
001120 1400-1500   WBD multi sc ops
(failed due to wrong config tables)
WBD multi sc ops
(failed due to wrong SC antenna)
WBD multi sc ops
(failed due to wrong config tables)
001120 1638-1643     EFW Orbit Sequencer test started  
001121 2245       E9.1 EFW HBR diagnostics
001121 2315       E9.2 STAFF HBR diagnostics
001121 2345       E10 WBD HBR diagnostics
001122 0006       E9.b WHISPER HBR diagnostics
001122 0041       E9.c WHISPER HBR diagnostics
001124 2139       F1 Full EFW tests
001124 2339       F2 Full WHISPER tests
001125 0240       F3 Full STAFF tests
001125 0340       F4 Full WBD BM2 tests
001125 0440       F5 Full WEC macro tests
001126 0100 DWP + EFW reset DWP + EFW reset DWP + EFW reset DWP + EFW reset
001127 1249-1349 WBD multi sc ops (OK) WBD multi sc ops (OK) WBD multi sc ops (partly OK) WBD multi sc ops
(failed due to low antenna slew rate)
001127 1800       F6a Full WEC macro tests (HBR)
001127 1900       F6b Full WEC macro tests (HBR)
001127 2030       F7 WEC interference tests (HBR)
001128 0516       WBD DSN diagnostics ??
001128 0546       F8 WEC interference tests (LBR)
001130 0300     F1 Full EFW tests (rerun)  
001130 0500     F2 Full WHISPER tests (rerun)  
001130 0800     F3 Full STAFF tests (rerun)  
001201 0600-0920       E7.4 WEC diagnostics (rerun)
001201 0930-0950       E8 WBD BM2 diagnostics (rerun)
001204 1616-1716 WBD multi sc ops? WBD multi sc ops? WBD multi sc ops?  
         

Back to WEC home page.

Last updated 2000-11-29 by Per-Arne Lindqvist